Lightmed LightLas Deux SLT

$23.000

LightLas Deux SLT delivers the perfect combination of power, precision, and versatility. Developed by LIGHTMED, a global leader in ophthalmic laser innovation, it enables practitioners to perform multiple treatments with one reliable device—enhancing both patient outcomes and clinic efficiency.

Description

LIGHTMED LightLas Deux SLT Laser System

The LIGHTMED LightLas Deux SLT is a cutting-edge dual-mode ophthalmic laser system designed for Selective Laser Trabeculoplasty (SLT) and YAG laser procedures. Engineered by LIGHTMED, a global leader in ophthalmic laser technology, this system delivers exceptional precision, reliability, and versatility for glaucoma management and posterior capsulotomy treatments.

Combining SLT and YAG functions in a single compact platform, the LightLas Deux SLT offers seamless switching between modes for efficient workflow and superior clinical performance. Its advanced optics and energy control ensure consistent results with minimal collateral tissue damage — providing optimal outcomes and patient safety.

LIGHTLas Deux SLT : A combined laser system for versatile ophthalmic therapy

The LIGHTLas Deux SLT represents the technological evolution of ophthalmic laser systems, offering a comprehensive, integrated platform that combines SLT (Selective Laser Trabeculoplasty), YAG and vitreolysis capabilities. It has been designed to meet contemporary clinical requirements in the treatment of glaucoma, posterior capsular opacities and vitreous floaters, while adapting to the growing needs of retinal treatment. This multifunctional system is recognised for its high reliability, energy precision and advanced features, offering practitioners an ergonomic and scalable solution.

The system features exclusive laser cavity technology and an intelligent thermal management circuit that eliminates performance variations in the KTP crystal. This ensures optimal shot-to-shot energy consistency, even during high-frequency use. This stability translates into increased therapeutic efficacy and a reduction in adverse effects such as punctures of intraocular lenses. In addition, the Gaussian profile design of the YAG beam enables precise tissue cutting, minimising the energy required for the optical break effect.

The high-resolution LED slit lamp and internal optics without a beam splitter provide a wide, clear view of the eye. The five-level magnification changer allows detailed visualisation of fine structures up to a global view of the fundus. Combined with a focal shift range of ±500 μm, this system offers precise control of the treatment plane while maintaining patient comfort.

In SLT mode, the system uses a low-energy 532 nm laser pulse that selectively targets pigmented cells in the trabeculum, triggering a natural immune response to improve aqueous humour drainage. This non-thermal, non-destructive and repeatable treatment is recognised as the first-line method for treating open-angle glaucoma. In vitreolysis mode, the dual targeting technology allows precise targeting of vitreous floaters while preserving the surrounding tissue.

Ergonomic and modular, the LIGHTLas Deux SLT is equipped with dual manual controls, an external chin rest for greater patient comfort, and a joystick-integrated firing system for increased precision. It can be supplemented with various modules such as the LIGHTLas 532, 577 or 810 to extend its capabilities to retinal photocoagulation, making this platform a true anterior and posterior treatment station.

The ingenious design of the LIGHTLas Deux SLT allows for simplified maintenance and reduced downtime, ensuring maximum availability for clinical practice. Its compatibility with mobile stations, video or photographic adapters and various types of therapeutic lenses makes it a scalable tool, adapted to evolving medical needs.

LIGHTLas Deux SLT is a comprehensive and reliable solution that offers ophthalmologists an infinite range of treatment options with optimal precision and safety.

Key Features:

  • Dual-Mode Laser Platform – Combines SLT and YAG capabilities in one integrated system.

  • 👁️ Precision Energy Delivery – Provides accurate targeting and uniform energy distribution for consistent results.

  • 💡 Advanced Optical Design – Delivers clear visualization and superior focus during laser procedures.

  • 🧠 Smart Control Interface – Intuitive touchscreen operation for simplified settings and quick mode transitions.

  • 🔄 Compact, Ergonomic Design – Streamlined system fits easily into any ophthalmic practice.

  • 🩺 Reliable & Safe – Ensures gentle tissue interaction and reduced risk of complications.

Applications:

  • Selective Laser Trabeculoplasty (SLT) for glaucoma management

  • Posterior capsulotomy

  • Peripheral iridotomy

  • General ophthalmic laser procedures

Technical Highlights:

  • Laser type: Frequency-doubled Q-switched Nd:YAG

  • SLT wavelength: 532 nm (green)

  • YAG wavelength: 1064 nm (infrared)

  • Pulse duration: 3 ns (YAG) / 3 ns Q-switched (SLT mode)

  • Energy range: Adjustable for precise treatment control

  • Interface: Touchscreen with programmable presets

  • Delivery: Integrated slit lamp with precise aiming beam

Why Choose the LightLas Deux SLT:

LightLas Deux SLT delivers the perfect balance of versatility, precision, and efficiency. By combining SLT and YAG functions in one robust platform, it simplifies workflow, reduces equipment footprint, and ensures optimal patient care for both glaucoma and capsulotomy treatments.

Reviews

There are no reviews yet.

Be the first to review “Lightmed LightLas Deux SLT”

Your email address will not be published. Required fields are marked *